TELE-DATA – Partner for the industry in Power Utility Communications
Phone +49 (0) 911 96269570

Protocol Simulators and Analyzers


PC-based control centres and protocol simulators / analyzers are available for the following protocols:

Supports codes for each product are interpreted as follows:

Protocols:
(Byte protocols shown in Bold )
Test Set GPT RCOM/RPT and RCOM/FEP
Stufe   Slave     Host   Downstream (Slave Side) Upstream (Host Side)
ABB Spa Bus A

C

C

A

B

**RP-570 A

C

C

C

C

**RP-571 A C C C C
ACS 3100 C C C B A
APEX CA C C C C C
ASEA  ADLP 80 C A C B B
ADLP 180 C A C B B
ASW  *LS RTU C C C B B
Amtrak SDLC C C C B B
BBCSI 6200 6-Bit C C C B B
12-Bit C C C B B
Bailey MPC C C C B B
Boeing SDLC C C C B B
CAE *Micro RTU C C C A (Normal & Listening) B
HDLC C C C A B
CDC Type 1 A A C A A
Type 1, 12 bit address A B C A A
Type 1 ASCII A C C B B
Type 2 A A C A A
Type 2 synchronous A C C B B
Type 2 extended C C C B B
CDT Types 1,2,3,4,5 C C C B B
Cegelec HN Z 66 S 11/15 C C C B B
Compumech CD-4150 C C C B B
Conitel 300 A C A A A
2000 A C C B B
2020 A A C A (Normal & Listening) A
*2025 A C C A A
2100B A C C B B
*2100H A C C B A (Listen Mode)
2100M A C C B B
3000 A C C B B
DNP 3 A A A A (Normal & Listening) A
3 Wan/Lan A C C A A
DYNAC DYNET A C C A B
ESCA Async C C C A B
Sync C C C B B
Ferranti Van Comm A C C B B
Fuji C C C C A
GE Multilin C C C A C
Getac 7020/4-BCH A A C A A
7020-LP A C C B B
Harris 5000/6000 A A C A A
Micro 2 C C C B B
Micro 3 C C C A B
Honeywell 7000 C C C B B
IEC 870-5- 101 A A A A (Normal & Listening) B
103 A A A A C
104 A C C C C
Indactic 33/1 A C C A B
33/41 A A C B B
33/41 Extended A A C B B
Landis and Gyr *Telegyr 6500 A C C B B
Telegyr 8979 A A C A A
Modbus ASCII A A A A A
RTU A A A A A
TCP A A C C C
Moore 9000 C C C B B
PG&E 2179 A A C B B
Pert 26/31 C C C B B
QEI/Quindar *QPLH C C C B B
Quics II C C C A A
*Quics IV C C C B B
Quantum DNP 1/QDIF A C C B B
Recon 1.1 A C C A B
Redac 70D A C C B B
70H A A C B B
Redsad C C C A C
Rockwell 5010 A C C A B
5011 (Standard) A C C B B
5011 (PSI) A C C B B
5012 A C C A B
SCADA Consultants A C C B B
Scadapac 1.0 C C C A B
5.0 A C C B B
SCA 2500 C C C A B
SCI *RDACS C C C B B
SEL 251 C C C A C
321 C C C A C
587 C C C A C
SES 92 A A C B B
Siemens Sinuat 8-FW/DPDM C C C A ( Listen Mode) C
Southern Services A C C B B
Southwestern Pub. Svc. Co. SPS C C C C C
Systems Control 5.0 A C C A B
5.4.1 A C C A A
5.5 A C C B B
6.0 A A C B B
Systems Northwest *11.1 A A C B B
*111 A C C B B
*Distribution A C C B B
Tano Model 5 C C C B B
Toshiba A C C C C
TLC 11M C C C C C
TRW 9550 A A C B B
System 9 A C C B B
DS-850 A C C C C
Valmet (Tejas) Series 3 A C C B B
Series 5 A C C B A
Series 5 Extended A C C B B
Westinghouse Wisp+ A A C C C
Wisp+ Extended A A C C C
Weston Recon 1 C C C C C

We are happy to receive your inquiries and advise you in complex scenarios.

TELE-DATA
Partner for the industry in Power Utility Communications

  • Am Wintergraben 2
    D-91189 Rohr
    Germany

  • +49 (0) 911 96269570